站内搜索
|
详细信息 Product Name: 0.5 Class AC Harmonics Multifunction Power Meter Model NO.: FU2200A Customized: Customized Certification: RoHS, ISO, CE, Kema Measured Signal: Continuous Wave Power Meter Connection: Terminal Theory: Electronic Meter Electric Equipment: 3p4w or 3p3w Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter, Panel Meter Installation: Indirect Connected Display: Digital Accuracy: 0.5% or 0.5s Voltage: 0-400V Frequency: 45-65Hz Phase Angle: 0-360.0 Power Factor: -1~0~1 Communication: RS485 or Ethernet Port Trademark: GFUVE Transport Package: Standard Export Box Specification: CE, ISO9001: 2008, IEC Origin: Beijing, China HS Code: 903033900 Product Description 0.5 class AC Harmonics Multifunction Power MeterFU2200A digital Ethernet power meter with data logger is a three-phase multifunction power and energy meter manufactured by GFUVE. It provides excellent value for monitoring power and energy management systems. It may be used as data gathering devices for intelligent power distribution or plant automation systems. All monitored data is available via a standard digital RS485 communication port, which is based on the Modbus RTU protocol.FU2200A Ethernet power meter has the PC software and the data logger function, which can set by end users from 1min to 60min intervals to record. You can read the data through a PC. Also, you can share the data in the Internet LAN. By the way, it can measure the harmonics. Back of power meter FU2200A with Ethernet port as photo shows here.FEATURESTrue-RMS measuring parametersANSI and IEC 0.2 accuracy classPower quality analysis4 quadrant energy2MB onboard memory, can be extended to 16MData loggingHigh-speed RS485, Ethernet port (option)Measure individual harmonics from 2ndto 49th(option)TOU, 4 Tariffs, 6 Seasons, 6 SchedulesThree years warrantyWith PC management software; web browse dataAPPLICATIonSMetering of distribution feeders, transformers, generators, capacitor banks and motorsMedium and low voltage systemsCommercial, industrial, utilityPower quality analysisData loggingMonitoring systemPARAMETERSElectrical parametersPower Supply (AC/DC)AC85-400V / DC85-330VPower consumption: <4VAMeasurement ParametersVoltage (Ph-N); Voltage (Ph-Ph); Current; Frequency; PF;Active Power(W); Reactive Power(Q); Apparent Power(S),2ndto 49thharmonics(option)HarmonicsTotal harmonics ratio of phase-voltageTotal harmonics ratio of current2ndto 49thharmonics ratio of phase-voltage2ndto 49thharmonics ratio of currentMaximum Value & Minimum ValueVoltage, current, frequency, active power, reactive power, apparent power,demandP,demandQ, demandS.ComputationForward active power energyReverse active power energyForward active power energyReverse reactive power energyMeasuring Range0-400V, 0-6A, 45-65Hz, -1 ~ 0 ~ 1Measuring AccuracyVoltage: 0.5%RD±0.05%FSCurrent: 0.5%RD±0.05%FSActive Power: 0.5%RD±0.05%FSReactive Power: 1.5%RD +0.05%FSApparent power: 0.5%RD +0.1%FSPower Factor: 0.5%RDFrequency: 0.05%RDActive Energy: 0.5%Maximum DemandIa, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutesDisplayBlue back-lit LCD Display5 display figures4 operation keysCommunicationSupport RS-485 interface port, 32 (128) NetworkingModBus-TCP/IP SNMP communication protocolEthernet 10/100M port (RJ45)Memory2M onboard memory,can be extended to 16M.Data looger interval can set by end users from 1min to 60min.The default is 15min.You can read the data through a PC, also you can select the data to diaplay and store from software.ProgrammableMeasuring system: 3P4W/3P3W etcTransformation Ratio: PT 1-10000; CT 1-10000Energy PulseProvides active & reactive energy pulse outputPulse parameters can be choosedRange: 0.1-10000kWh/kvarhDry contact output (1Ax100V)Connection Mode3P4W, 3P4W BAL, 3P3W, 3P3W BAL, 1P3W, 1P2WBaudBaud: 1200-57600, Standard 38400Mechanical parametersDimensions (L x W x H) (mm)96 x 96 x 12.8MountingPanel mountingTrepanning: 92x92mmThe thickness of installation: 51mmEnvironmental conditionsTemperature-5 to +50 °CHumidity20%-95%RH, without condensationWarrantyThree years warrantyINDEXParametersAccuracyResolutionMeasuring rangeShow on the displayVoltage0.20%0.01V0-400V0.5-500kVCurrent0.20%0.01mA0-6.5A5mA-50000AActive power0.50%0.2W0-2400W/phase-9999MW to +9999MWReactive power2%0.2var0-2400var/phase-9999Mvar to +9999MvarApparent power0.50%0.2VA0-2400VA/phase0-9999MVAActive demand0.50%0.2W0-2400W/phase-9999MW to +9999MWReactive demand2%0.2var0-2400var/phase-9999Mvar to +9999MvarApparent demand0.50%0.2VA0-2400VA/phase0 to 9999MVAPower factor0.0050.0001-2-2Frequency0.01Hz0.01Hz45.000-65.000Hz45.000-65.000HzActive energy0.5%,0.2% (Option)0.001kWh0-999999.999kWh0-99999999.9kWhReactive energy2%0.001kvarh0-999999.999kvarh0-99999999.9kvarhApparent energy0.50%0.001VAh0-999999.999kVAh0-99999999.9kVAhPhase angle0.1°0.01°0-359.99°0-359.99°Unbalance2%0.01%0-300.00%0-300.00%PT ratio11-10000CT ratio11-10000Address code11-253
|