站内搜索
|
详细信息 Product Name: Multi-Function Double Clamp Digital Phase Angle Meter Model NO.: GF211B Voltage: Low Voltage Stucture: Electromagnetic Display: Digital Certification: CE, ISO, RoHS Customized: Customized Brand: Gfuve Accuracy: 0.5% Phase: 0-360.0 Deg U1, U2: 0-500V AC I1, I2: 0-10A AC Types: Phase Angle Meter Weight: 0.26kg Dimension: 185 Mmx85mmx41mm PF: -1-0-1 Color: White and Orange LCD: 2.8 Inch Trademark: GFUVE Transport Package: Standard Export Carton Specification: CE, ISO9001: 2008, IEC Origin: Beijing, China HS Code: 9030849000 Product Description GF211B Multi-Function Double Clamp Digital Phase Angle MeterApplicationGF211B multi-function double clamp digital phase angle meter is a multi-functional portable instrument. It can measure not only alternating voltage (U), but also alternating current (I), frequency (F), active power (P), reactive power (Q), power factor (PF) and so on. Its important function is to measure phase angle between two voltages, between two current or between voltage and current. The current signal is obtained by the clamp current transformer without cutting off current wire. IGF211B multi-function double clamp digital phase angle metercan discern inductive circuit and capacitive circuit; Can directly read differential protection phase among every unit of CT; Can check connection of transformer; Measure two way voltage phase sequence; Can check whether the meter connection is right or not; Can evaluate the running speed of electric kWh meter. It has high resolution of current, so can be used as a leakage current meter. It is an ideal choice for electric power bureau, factories, mine, petroleum -chemistry enterprises, metallurgy factories and so on.Specifications2.1 Scale2.1. 1 Phase: 0~360°2.1. 2 AC Voltage: 0~500V2.1. 3 AC Current: 200mA / 2A / 10A2.1. 4 Frequency: 20~65Hz2.1. 5 Active power accuracy: 1%, resolution 0.01W2.1. 6 Power factor: -1~0~1, resolution 0.0012.2 Fundamental error (under standard operating environment)2.2.1 Standard Condition2.2. 2 Phase accuracy 1.0% FS2.2.3 Voltage accuracy2.2.4 Current accuracy2.3 Input impedance:2.3. 1 1MΩ When measure voltage2.3. 2 input voltage impedance>120KΩ When measure phase2.4 operation condition2.5 additional error2.5. 1 When measure phase angle, the voltage and the current are in the range of the operating conditions, the additional error is less than the fundamental error.2.5. 2 When measure current, the error LED by wires away from center of clamps is less than the fundamental error.2.6 Safety specification2.6. 1 Resistance to voltageThe meter can resist 1000V (AC sinewave, 50Hz or 60 Hz) for 1 minute both between the meter circuit and the meter case; Between input joint U1 and U2 can resist 500V(AC sinewave, 50Hz or 60 Hz) for 1 minute.2.6. 2 Insulation resistanceThe resistance both between the meter circuit and the meter surface and between the terminals U1 and U2 is greater than 100MΩ .2.7 Power supply 3.7V batteries.2.8 Size and Weight: 185 mmX85mmX41mm 0.26KgAccessoriesScaleAccuracyResolution200V1.0FS0.1V500V1.0FS1V TemperatureMoistureWave FormFrequencyWire PositionPhase measurementvoltagecurrent23±5degrees<65%Sine wave Distortion ≤1%50± 2Hz, 60± 2Hzcenter of clamp100V± 25V1A±0.2A
|